NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Fracture Toughness of Thin Plates by the Double-Torsion Test MethodDouble torsion testing can produce fracture toughness values without crack length measurement that are comparable to those measured via standardized techniques such as the chevron-notch, surface-crack-in-flexure and precracked beam if the appropriate geometry is employed, and the material does not exhibit increasing crack growth resistance. Results to date indicate that 8 < W/d < 80 and L/W > 2 are required if crack length is not considered in stress intensity calculations. At L/W = 2, the normalized crack length should be 0.35 < a/L < 0.65; whereas for L/W = 3, 0.2 < a/L < 0.75 is acceptable. In addition, the load-points need to roll to reduce friction. For an alumina exhibiting increasing crack growth resistance, values corresponding to the plateau of the R-curve were measured. For very thin plates (W/d > 80) nonlinear effects were encountered.
Document ID
20070002899
Acquisition Source
Glenn Research Center
Document Type
Conference Paper
Authors
Salem, Jonathan A.
(NASA Glenn Research Center Cleveland, OH, United States)
Radovic, Miladin
(Oak Ridge National Lab. TN, United States)
Lara-Curzio, Edgar
(Oak Ridge National Lab. TN, United States)
Nelson, George
(Oak Ridge National Lab. TN, United States)
Date Acquired
August 24, 2013
Publication Date
January 1, 2006
Subject Category
Structural Mechanics
Report/Patent Number
ICACC-S1-070-2006
Meeting Information
Meeting: 30th International Conference and Exposition on Advanced Ceramics and Composites
Location: Cocoa Beach, FL
Country: United States
Start Date: January 22, 2006
End Date: January 27, 2006
Funding Number(s)
CONTRACT_GRANT: DE-AC05-00OR-22725
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available