Comparison of NASTRAN and MITAS nonlinear thermal analyses of a convectively cooled structureComparative steady state nonlinear thermal analyses of a scramjet fuel injection strut are presented. The analyses were performed using the NASTRAN finite element program and MITAS, a lumped-parameter thermal analyzer. The strut is subjected to aerodynamic heating on two sides and is internally cooled by hydrogen flowing from internal manifolds through heat exchangers bonded to the primary structure. Based on coolant temperatures determined by MITAS, NASTRAN predicted temperature distributions throughout the strut which were in close agreement with similar MITAS predictions.