Time transfer by IRIG-B time code via dedicated telephone linkMeasurements were made of the stability of time transfer by the IRIG-B code over a dedicated telephone link on a microwave system. The short and long term Allan Variance was measured on both types of microwave system, one of which is synchronized, the other having free local oscillators. The results promise a time transfer accuracy of 10 microns. The paper also describes a prototype slave clock designed to detect interference in the IRIG-B code to ensure local time is kept during such interference.