Comparison of Standard and Heart-pacer Type 3rd Electrodes in Design Variable CellsNine packs of sealed aerospace nickel cadmium cells were put on life test in February 1979. Each 5 cell pack contained one cell with a standard sensor signal electrode and one cell with a new heart pacer sensor signal electrode. Testing was discontinued in May 1983 and the signal electrode performance data was studied. It was found that the heart pacer electrode generally provided a greater voltage swing over a cycle; that both types of electrodes lost significant sensitivity during life, and that both types of electrodes show great signal variation from cell to cell.
Document ID
19840025623
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Morrow, G. W.
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
August 12, 2013
Publication Date
September 1, 1984
Publication Information
Publication: The 1983 Goddard Space Flight Center Battery Workshop
Subject Category
Electronics And Electrical Engineering
Accession Number
84N33694
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.