Photovoltaic module spread-of-flame testingPhotovoltaic modules used in solar energy conversion are tested for flammability. Class B burning brand tests were conducted with the following results: module glass shattered and hydrocarbon encapsulants ignited. Penetration of back surface material was the prime cause of failure. Materials with greater flame and heat resistance are under consideration to increase back surface integrity up to Class A burning brand standard. The most promising is stainless steel foil.
Document ID
19850024135
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Sugimura, R. S.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Otth, D. H.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Arnett, J. C.
(ARCO Solar, Inc.)
Date Acquired
August 12, 2013
Publication Date
October 1, 1984
Publication Information
Publication: Proc. of the 24th Project Integration Meeting
Subject Category
Energy Production And Conversion
Accession Number
85N32448
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available