NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
The AXAF VETA test - An overviewResults of a battery of X-ray tests on the AXAF Verification Engineering Test Article (VETA) X-ray optics which were performed shortly after their fabrication are presented. The optics, a paraboloid, and a hyperboloid in the classic Wolter-1 configuration are the outer mirrors of what is now the AXAF-I mission. The optical elements are each about 1.2 m in diameter and 0.8 m long. The principal proof that the optics met their specification was to demonstrate that the angular resolution was at least 0.5 arcsec. The final result was an angular resolution smaller than 0.25 arcsec.
Document ID
19930055605
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Weisskopf, Martin C.
(NASA Marshall Space Flight Center Huntsville, AL, United States)
Date Acquired
August 16, 2013
Publication Date
January 1, 1993
Publication Information
Publication: In: Multilayer and grazing incidence X-ray(EUV optics for astronomy and projection lithography; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992 (A93-39601 15-74)
Publisher: Society of Photo-Optical Instrumentation Engineers
Subject Category
Optics
Accession Number
93A39602
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.
No Preview Available