NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
The Ames Power Monitoring SystemThe Ames Power Monitoring System (APMS) is a centralized system of power meters, computer hardware, and specialpurpose software that collects and stores electrical power data by various facilities at Ames Research Center (ARC). This system is needed because of the large and varying nature of the overall ARC power demand, which has been observed to range from 20 to 200 MW. Large portions of peak demand can be attributed to only three wind tunnels (60, 180, and 100 MW, respectively). The APMS helps ARC avoid or minimize costly demand charges by enabling wind-tunnel operators, test engineers, and the power manager to monitor total demand for center in real time. These persons receive the information they need to manage and schedule energy-intensive research in advance and to adjust loads in real time to ensure that the overall maximum allowable demand is not exceeded. The APMS (see figure) includes a server computer running the Windows NT operating system and can, in principle, include an unlimited number of power meters and client computers. As configured at the time of reporting the information for this article, the APMS includes more than 40 power meters monitoring all the major research facilities, plus 15 Windows-based client personal computers that display real-time and historical data to users via graphical user interfaces (GUIs). The power meters and client computers communicate with the server using Transmission Control Protocol/Internet Protocol (TCP/IP) on Ethernet networks, variously, through dedicated fiber-optic cables or through the pre-existing ARC local-area network (ARCLAN). The APMS has enabled ARC to achieve significant savings ($1.2 million in 2001) in the cost of power and electric energy by helping personnel to maintain total demand below monthly allowable levels, to manage the overall power factor to avoid low power factor penalties, and to use historical system data to identify opportunities for additional energy savings. The APMS also provides power engineers and electricians with the information they need to plan modifications in advance and perform day-to-day maintenance of the ARC electric-power distribution system.
Document ID
20110024172
Acquisition Source
Ames Research Center
Document Type
Other - NASA Tech Brief
Authors
Osetinsky, Leonid
(Jacobs Sverdrup Technology, Inc. Hampton, VA, United States)
Wang, David
(NASA Ames Research Center Moffett Field, CA, United States)
Date Acquired
August 25, 2013
Publication Date
June 1, 2003
Publication Information
Publication: NASA Tech Briefs, June 2003
Subject Category
Man/System Technology And Life Support
Report/Patent Number
ARC-14909
Distribution Limits
Public
Copyright
Public Use Permitted.