NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Long term tests of a SNAP-19 thermoelectric generator.Results of tests performed on a SNAP 19 thermoelectric generator, SN-20. The SN-20 generator was tested for approximately 37,000 hours using electrical heating to simulate the heat released by isotope decay. After 27,000 hours of operation the output power from the generator decreased to approximately 1/3 of the beginning of life value while the internal resistance increased by a factor of 5. Analysis of the test results, confirmed by preliminary metallographic examination, indicated that the output power degradation was the result of excessive sublimation of the thermoelectric material and loss of the hot junction bond due to the depletion of the internal cover gas. This also resulted in excessive junction temperatures. Comparison is made with the behavior observed from the two flight generators and a tentative conclusion is advanced as to the reason for their failure.