NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Continuous high pressure lump coal feeder design studyA continuous lump coal dry feeder was developed for a pressurized fluidized bed combustor. The approach was to adapt the commercially available Fuller-Kinyon pump to feed coal against a pressure differential of 100 psi or more. The pump was modified and tests performed at various pressure differentials, with differently pitched screws, various screw rotational speeds, and various seal lengths and configurations. Successful operation of the modified Fuller-Kinyon pump was generally limited to pressure differentials of 60 psi or less. Although the results are not conclusive, test data and observations were made that indicated that higher pressure differentials could be attained by further modifications of the test setup. In particular, it is recommended that further testing be performed after replacing the 40-horsepower pump motor presently in the test setup with a motor having a significantly high power rating (thereby allowing pump operation with longer seals and at higher pressure differentials than those tested so far).
Document ID
19780005310
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Fields, S. F.
(GARD, Inc. Niles, IL, United States)
Date Acquired
August 9, 2013
Publication Date
September 15, 1977
Publication Information
Publication: JPL Proc. of the Conf. on Coal Feeding Systems
Subject Category
Mechanical Engineering
Accession Number
78N13253
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available