Material handling systems for the fluidized-bed combustion boiler at Rivesville, West VirginiaThe 300,000 lbs/hr steam capacity multicell fluidized-bed boiler (MFB) utilizes complex material handling systems. The material handling systems can be divided into the following areas: (1) coal preparation; transfer and delivery, (2) limestone handling system, (3) fly-ash removal and (4) bed material handling system. Each of the above systems are described in detail and some of the potential problem areas are discussed. A major potential problem that exists is the coal drying system. The coal dryer is designed to use 600 F preheated combustion air as drying medium and the dryer effluent is designed to enter a hot electrostatic precipitator (730 F) after passage through a cyclone. Other problem areas to be discussed include the steam generator coal and limestone feed system which may have operating difficulties with wet coal and/or coal fines.
Document ID
19780005322
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Branam, J. G.
(Mitre Corp. McLean, VA, United States)
Rosborough, W. W.
(Mitre Corp. McLean, VA, United States)
Date Acquired
August 9, 2013
Publication Date
September 15, 1977
Publication Information
Publication: JPL Proc. of the Conf. on Coal Feeding Systems
Subject Category
Mechanical Engineering
Accession Number
78N13265
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available