NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Effects of 1-MeV gamma radiation on a multi-anode microchannel array detector tubeA multianode microchannel array (MAMA) detector tube without a photocathode was exposed to a total dose of 1,000,000 rads of 1-MeV gamma radiation from a Co-60 source. The high-voltage characteristic of the microchannel array plate, average dark count, gain, and resolution of pulse height distribution characteristics showed no degradation after this total dose. In fact, the degassing of the microchannels induced by the high radiation flux had the effect of cleaning up the array plate and improving its characteristics.
Document ID
19790053268
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
External Source(s)
Authors
Timothy, J. G.
(Colorado, University Boulder, Colo., United States)
Bybee, R. L.
(Ball Corp. Ball Aerospace Systems, Boulder, Colo., United States)
Date Acquired
August 9, 2013
Publication Date
June 1, 1979
Publication Information
Publication: Review of Scientific Instruments
Volume: 50
Subject Category
Instrumentation And Photography
Accession Number
79A37281
Funding Number(s)
CONTRACT_GRANT: NSG-7459
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.
No Preview Available