Full-coverage film coolingTranspiration cooling is treated and then full coverage discrete hole injection for three injection orientations. Spacings with pitch to diameter ratios of 5 and 10 are discussed. The array is staggered, with the transverse pitch and the streamwise pitch the same. Results are presented in terms of the Stanton number using the heat transfer coefficient defined in terms of the difference between the wall temperature and the free stream temperature. Two values of Stanton number are provided for each situation: one with the injectant at wall temperature, and the other with the injectant at free stream temperature. These two values are equivalent to knowing the heat transfer coefficient and the adiabatic effectiveness. The heat transfer coefficient thus defined is used with the actual wall temperature to and the actual gas temperature to calculate the heat load. The principle of superposition thus invoked is valid exactly when the governing equations are linear.