Visible charge-coupled device (CCD) focal plane design considerations for multispectral applicationsThe typical Multispectral Linear Array (MLA) Instrument mission would be to gather high-resolution, radiometrically accurate earth resources data in several spectral bands over a prolonged period of time. These bands would include the visible (VIS), near infrared (NIR) and short wavelength infrared. Silicon charge-coupled imaging devices (CCDs) can be assembled into contiguous pixel focal planes which will cover the VIS/NIR region and operate reliably for several years in a space environment. A typical MLA focal plane would have approximately 12,000 pixels, with a pixel-to-pixel registration requirement on the order of + or - 0.1 pixel. The technology to assemble such focal planes has been developed and is described. The problem of polarization sensitivity associated with certain types of focal plane assemblies is addressed. Radiation effects on CCDs are also discussed, and a practical solution to the problem through the use of shielding is described.
Document ID
19840044427
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Sadowski, H. (Fairchild Weston Systems, Inc. Syosset, NY, United States)