Qualification of S-glass/epoxy thermal isolator bandsUnidirectional fiberglass reinforced epoxy structures have been evaluated as thermal isolator tension straps for the charge-coupled devices on the Hubble Space Telescope's Wide Field/Planetary Camera. Mechanical and thermal properties are reported for filament-wound S-2 glass in a generic epoxy resin and compared to S-901 glass bands used on a previous camera. Measurements were performed on very small paper clip-shaped bands. Probably the smallest in length and have a load carrying mean cross sectional area of only 0.00024 square inches.