An analysis of two classes of grazing incidence mirrors for use with Rowland circle spectrometersResults are presented of a comparative analysis of Hettrick Bowyer Type II (HBII) and Wolter-Schwarzschild Type II (WSII) optics for use with Rowland circle spectrometers. The HBII can substitute, with few exceptions, for a WSII in any Rowland circle with little change in spectrometer performance or design. However, the HBII telescope offers several clear advantages over the WSII in these configurations. Because the HBII employs a virtual focus, it requires a much shorter instrument length than a WSII. For example, a 3-m Rowland circle spectrometer, fed by an optimized, f/10, 1-m diameter WSII, has a total instrument length of 6 m. If a HBII is used to feed the identical spectrometer, the entire instrument length can be as little as 3 m. In addition, the improved imaging gained with the larger graze angles of the HBII design results in better resolution in slitless operation modes.
Document ID
19870049151
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Green, James (California Univ. Berkeley, CA, United States)
Bowyer, Stuart (California, University Berkeley, United States)