Failure mechanism characterization of platinum alloyThis article describes procedures and results of testing performed on a platinum/10-percent rhodium, thin-wall tubular product. The purpose of the testing was to develop exemplar SEM fractographs to be used to characterize failures under various environmental conditions. Conditions evaluated for the platinum alloys included high temperature, hydrogen environment, braze metal contamination, and cyclic loading.
Document ID
19870057855
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Rosen, J. M. (Rockwell International Corp. Canoga Park, CA, United States)
Mcfarlen, W. T. (Rockwell Internaational Corp. Rocketdyne Div., Canoga Park, CA, United States)