NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Washing Off Polyurethane Foam InsulationJet of hot water removes material quickly and safely. Simple, environmentally sound technique found to remove polyurethane foam insulation from metal parts. Developed for (but not limited to) use during rebuilding of fuel system of Space Shuttle main engine, during which insulation must be removed for penetrant inspection of metal parts.
Document ID
19900000674
Acquisition Source
Legacy CDMS
Document Type
Other - NASA Tech Brief
Authors
Burley, Richard K.
(Rockwell International Corp.)
Fogel, Irving
(Rockwell International Corp.)
Date Acquired
August 14, 2013
Publication Date
December 1, 1990
Publication Information
Publication: NASA Tech Briefs
Volume: 14
Issue: 12
ISSN: 0145-319X
Subject Category
Fabrication Technology
Report/Patent Number
MFS-29578
Accession Number
90B10674
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.

Available Downloads

There are no available downloads for this record.