Reorientation of rotating fluid in microgravity environment with and without gravity jittersIn a spacecraft design, the requirements of settled propellant are different for tank pressurization, engine restart, venting, or propellant transfer. The requirement to settle or to position liquid fuel over the outlet end of the spacecraft propellant tank prior main engine restart poses a microgravity fluid behavior problem. In this paper, the dynamical behavior of liquid propellant, fluid reorientation, and propellant resettling have been carried out through the execution of supercomputer CRAY X-MP to simulate the fluid management in a microgravity environment. Results show that the resettlement of fluid can be accomplished more efficiently for fluid in rotating tank than in nonrotating tank, and also better performance for gravity jitters imposed on fluid settlement than without gravity jitters based on the amount of time needed to carry out resettlement period of time between the initiation and termination of geysering.
Document ID
19900032833
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Hung, R. J. (Alabama Univ. Huntsville, AL, United States)
Lee, C. C. (Alabama, University Huntsville, United States)
Shyu, K. L. (Alabama Univ. Huntsville, AL, United States)