Bulk thermal capacity determination for Li/BCX and Li/SOClN2 cellsThe bulk heat capacities of Li/BCX and Li/SOClN2 cells were determined at 0 and 100 percent depth-of-discharge for 2.0 V cut-off voltage, in the temperature range 0 to 60 C by a method that did not involve the destruction of the cell nor the contact of cell with a liquid. The heat capacities are found to be dependent on state-of-charge, increasing with depth-of-discharge. The Li/BCX DD-cell has a lower heat capacity than a high rate Li/SOCl2 D-cell. The results obtained by this method compare favorably well with results reported in the literature through other methods. The bulk heat capacities of the cells did not change significantly in the temperature range 0 to 60 C.