Electrical characterization of a Space Station Freedom alpha utility transfer assemblyElectrical testing of a utility transfer assembly (UTA) developmental unit performed from January 22 through February 25, 1992 at the NASA Lewis Research Center using the power management and distribution dc test bed. The dc resistance and steady state temperatures recorded are evidence of the UTA's high electrical transfer efficiency. The impedance test results suggest the total inductance of a UTA crossing pair is substantially higher than originally specified in the Space Station Electrical Power System Architectural Control Document.
Document ID
19930042104
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Yenni, Edward J. (Rockwell International Corp. Cleveland, OH, United States)
Date Acquired
August 16, 2013
Publication Date
January 1, 1992
Publication Information
Publication: In: IECEC '92; Proceedings of the 27th Intersociety Energy Conversion Engineering Conference, San Diego, CA, Aug. 3-7, 1992. Vol. 6 (A93-25851 09-44)