Thermal systems analysis for the Space Infrared Telescope Facility dewarThermal systems analysis models were used to design SFHe cooled dewar for the Space Infrared Telescope Facility (SIRTF), a 1 m class cryogenically cooled observatory for IR astronomy. The models are capable of computing both the heat leaks into the dewar and the operating temperature of a SFHe tank. The models are aimed at predicting the ability of the SIRTF cryogenic system to satisfy a five-year mission lifetime requirement and maintain the SFHe tank operating temperature of 1.25 K to provide sufficient cooling for science instruments and the optical system. The thermal models are very detailed and very fast with a typical steady state run of about 20 sec on a VAX minicomputer.