Automated Test Systems for Toxic Vapor DetectorsThe NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.
Document ID
19970017916
Acquisition Source
Kennedy Space Center
Document Type
Conference Paper
Authors
Mattson, C. B.
(I-NET, Inc. Cocoa Beach, FL United States)
Hammond, T. A.
(I-NET, Inc. Cocoa Beach, FL United States)
Schwindt, C. J.
(I-NET, Inc. Cocoa Beach, FL United States)
Date Acquired
August 17, 2013
Publication Date
March 1, 1997
Publication Information
Publication: The 1997 JANNAF Propellant Development and Characterization Subcommittee and Safety and Environmental Protection Subcomittee Joint Meeting
Volume: 1
Subject Category
Instrumentation And Photography
Accession Number
97N20027
Funding Number(s)
CONTRACT_GRANT: NAS10-11943
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.

Available Downloads

There are no available downloads for this record.
No Preview Available