FTIR Study of Vapor Offgassing from Orbiter Tile Re-Waterproofing MaterialsThe work presented in this paper was performed to identify and quantify the offgassing behavior of alternative re-waterproofmg materials under investigation for application to Shuttle Orbiter Thermal Protection System (TPS) tile and blanket materials. The purpose was to determine whether the new materials would cause a problem with the operational analysis of residual vapors using the current portable vapor analyzer, a Miran 203. The materials investigated were limited to dimethylethoxysilane (DMES) and proposed solvent selected as suitable for use in re-waterproofing Orbiter TPS. The solvent was selected in another phase of the overall project. Obiter TPS tiles were injected with the re-waterproofing materials under constant conditions of temperature, relative humidity and air flow. The vapor concentrations of offgassing materials were monitored using Fourier Transform Infrared (FTIR) multi-component analysis, and with the Miran 203 instruments. The procedure was to record the time dependent concentrations of offgassing materials as analyzed by the FTIR, and the time response of the Miran 203 to the materials under consideration. The FTIR was calibrated for vapor phase DMES, tetramethyldisiloxane (TMDS), ethanol and the hydrocarbon solvents to be used to dilute the DMES for application to the TPS tile. The Miran 203 was calibrated for the operational measurement of DMES airborne vapors. The FTIR data, shows for the first time that the principal product which offgases from the tile after the first hour is not DMES, but TMDS and ethanol. The Miran 203 response to TMDS is the primary reading after the re-waterproofing operation is completed. The operational use of the Miran 203 to measure DMES vapors after re-waterproofmg operations has been responding to TMDS. The results of this study suggest that the historical complaints that have contributed to the low threshold limit value (TLV) for DMES concentrations, as read with the Miran 203, are actually based on instrumental responses to TMDS, for which no other toxicology information is available at this time. While there is some interference, the use of the tested hydrocarbon solvents does not adversely affect the response of the Miran 203.
Document ID
19990110102
Acquisition Source
Kennedy Space Center
Document Type
Conference Paper
Authors
Mattson, C. B.
(Dynacs Engineering Co., Inc. Cocoa Beach, FL United States)
Date Acquired
August 19, 2013
Publication Date
April 1, 1999
Publication Information
Publication: JANNAF 28th Propellant Development and Characterization Subcommittee and 17th Safety and Environmental Protection Subcommitte Joint Meeting
Volume: 1
Subject Category
Nonmetallic Materials
Funding Number(s)
CONTRACT_GRANT: NAS10-98001
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.

Available Downloads

There are no available downloads for this record.
No Preview Available