A Sensor for Obtaining Ablation RatesA variable-capacitance ablation-rate sensor which allows continuous measurements of ablation rates for Teflon and similar polymers has been developed and tested i n an ethylene-heated high-temperature jet at stagnation temperatures ranging from 2,400 deg to 3,800 deg F. The data (length changes) were measured by using the same telemeter equipment as that used in rocket-propelled flight vehicles.Results indicate measurement error to be a maximum of 4 percent between the telemetered length changes and the length changes that were obtained from photographic records of the test.