NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Rapid direct methods for enumeration of specific, active bacteria in water and biofilmsConventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between results obtained with the ChemScan and traditional plate counts of mixed natural bacterial populations in water. The continuing evolution of these methods will be valuable in the rapid and accurate analysis of environmental samples.
Document ID
20040088794
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
Authors
McFeters, G. A.
(Montana State University Bozeman, United States)
Pyle, B. H.
Lisle, J. T.
Broadaway, S. C.
Date Acquired
August 21, 2013
Publication Date
January 1, 1999
Publication Information
Publication: Symposium series (Society for Applied Microbiology)
Volume: 85
Issue: 28
ISSN: 1467-4734
Subject Category
Life Sciences (General)
Funding Number(s)
CONTRACT_GRANT: EEC8-907039
Distribution Limits
Public
Copyright
Other
Keywords
Review, Tutorial
Review
NASA Discipline Environmental Health
Non-NASA Center

Available Downloads

There are no available downloads for this record.
No Preview Available