Mass transfer in a 1370 C (2500 F) lithium thermal convection loopExperimental results from a test to evaluate interstitial element mass transfer effects on T-111, ASTAR 811C, and ASTAR 1211C after 5000 hours in flowing lithium at 1370 C (2500 F) are presented. No gross corrosion effects were observed. However, hafnium and nitrogen transfer to cooler regions within the loop were noted. Oxygen was in general removed from test specimens, but there was no evidence to indicate that it was a major factor in the mass transfer process. Carbon and hydrogen transfer were not detected.
Document ID
19740008105
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Scheuermann, C. M.
(NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
September 3, 2013
Publication Date
February 1, 1974
Subject Category
Materials, Metallic
Report/Patent Number
NASA-TM-X-2986
E-7627
Accession Number
74N16218
Funding Number(s)
PROJECT: RTOP 501-21
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.