NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Heat pipe design handbook, part 2The utilization of a digital computer code for heat pipe analysis and design (HPAD) is described which calculates the steady state hydrodynamic heat transport capability of a heat pipe with a particular wick configuration, the working fluid being a function of wick cross-sectional area. Heat load, orientation, operating temperature, and heat pipe geometry are specified. Both one 'g' and zero 'g' environments are considered, and, at the user's option, the code will also perform a weight analysis and will calculate heat pipe temperature drops. The central porous slab, circumferential porous wick, arterial wick, annular wick, and axial rectangular grooves are the wick configurations which HPAD has the capability of analyzing. For Vol. 1, see N74-22569.
Document ID
19740026289
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Skrabek, E. A.
(Dynatherm Corp. Cockeysville, MD, United States)
Date Acquired
September 3, 2013
Publication Date
August 1, 1972
Subject Category
Thermodynamics And Combustion
Report/Patent Number
DTM-72-3-PT-2
NASA-CR-134265
Report Number: DTM-72-3-PT-2
Report Number: NASA-CR-134265
Accession Number
74N34402
Funding Number(s)
CONTRACT_GRANT: NAS9-11927
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.