Wall mounted heat exchanger characterizationAnalytical models are presented for describing the heat and mass transfer and the energy distribution in the contents of a cryogenic propellant tank, under varying gravity levels. These models are used to analytically evaluate the effectiveness of a wall heat exchanger as a means of controlling the pressure in the tank during flight and during fill operations. Pressure and temperature histories are presented for tanks varying in size from 4 to 22.5 feet in diameter and gravity levels from 0-1. Results from the subscale test program, utilizing both non-cryogenic and cryogenic fluid, designed to evaluate a tank wall heat exchanger are described and compared with the analytical models. Both the model and test results indicate that a passive tank wall heat exchanger can effectively control tank pressure. However, the weight of such a system is considerably higher than that of an active mixer system.
Document ID
19750008695
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Bullard, B. R.
(Lockheed Missiles and Space Co. Sunnyvale, CA, United States)
Date Acquired
September 3, 2013
Publication Date
January 1, 1975
Subject Category
Fluid Mechanics And Heat Transfer
Report/Patent Number
LMSC-D465537
NASA-CR-134536
Report Number: LMSC-D465537
Report Number: NASA-CR-134536
Accession Number
75N16767
Funding Number(s)
CONTRACT_GRANT: NAS3-16769
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available