NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Hand-Eye Calibration of RobonautNASA's Human Space Flight program depends heavily on Extra-Vehicular Activities (EVA's) performed by human astronauts. EVA is a high risk environment that requires extensive training and ground support. In collaboration with the Defense Advanced Research Projects Agency (DARPA), NASA is conducting a ground development project to produce a robotic astronaut's assistant, called Robonaut, that could help reduce human EVA time and workload. The project described in this paper designed and implemented a hand-eye calibration scheme for Robonaut, Unit A. The intent of this calibration scheme is to improve hand-eye coordination of the robot. The basic approach is to use kinematic and stereo vision measurements, namely the joint angles self-reported by the right arm and 3-D positions of a calibration fixture as measured by vision, to estimate the transformation from Robonaut's base coordinate system to its hand coordinate system and to its vision coordinate system. Two methods of gathering data sets have been developed, along with software to support each. In the first, the system observes the robotic arm and neck angles as the robot is operated under external control, and measures the 3-D position of a calibration fixture using Robonaut's stereo cameras, and logs these data. In the second, the system drives the arm and neck through a set of pre-recorded configurations, and data are again logged. Two variants of the calibration scheme have been developed. The full calibration scheme is a batch procedure that estimates all relevant kinematic parameters of the arm and neck of the robot The daily calibration scheme estimates only joint offsets for each rotational joint on the arm and neck, which are assumed to change from day to day. The schemes have been designed to be automatic and easy to use so that the robot can be fully recalibrated when needed such as after repair, upgrade, etc, and can be partially recalibrated after each power cycle. The scheme has been implemented on Robonaut Unit A and has been shown to reduce mismatch between kinematically derived positions and visually derived positions from a mean of 13.75cm using the previous calibration to means of 1.85cm using a full calibration and 2.02cm using a suboptimal but faster daily calibration. This improved calibration has already enabled the robot to more accurately reach for and grasp objects that it sees within its workspace. The system has been used to support an autonomous wrench-grasping experiment and significantly improved the workspace positioning of the hand based on visually derived wrench position. estimates.
Document ID
20100033083
Acquisition Source
Johnson Space Center
Document Type
Conference Paper
Authors
Nickels, Kevin
(Trinity Univ. San Antonio, TX, United States)
Huber, Eric
(Metrica, Inc. Houston, TX, United States)
Date Acquired
August 25, 2013
Publication Date
April 26, 2004
Subject Category
Cybernetics, Artificial Intelligence And Robotics
Report/Patent Number
JSC-CN-8289
Meeting Information
Meeting: IEEE 2004 International Conference on Robotics and Automation
Location: New Orleans, LA
Country: United States
Start Date: April 26, 2004
End Date: May 1, 2004
Sponsors: Institute of Electrical and Electronics Engineers
Distribution Limits
Public
Copyright
Public Use Permitted.
No Preview Available