Electrometer has automatic zero bias controlZero biasing circuit in a vibrating reed type electrometer counterbalances residual potential. It charges a capacitor to the residual potential and connects that capacitor in series with the vibrating reed so that the voltages cancel. This enables the electrometer to read zero output potential in the absence of an input current.
Document ID
19650000240
Acquisition Source
Legacy CDMS
Document Type
Other - NASA Tech Brief
Date Acquired
August 2, 2013
Publication Date
August 1, 1965
Subject Category
Electronic Components And Circuits
Report/Patent Number
GSC-350
Report Number: GSC-350
Accession Number
65B10242
Funding Number(s)
CONTRACT_GRANT: NAS5-4718
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.