Multiple temperatures sampled using only one reference junctionIn a multitemperature sampling system where the reference thermocouples are a distance from the test thermocouples, an intermediate thermal junction block is placed between the sets of thermocouples permitting switching between a single reference and the test thermocouples. This reduces the amount of cabling, reference thermocouples, and cost of the sampling system.