Space shuttle: Heat transfer rate measurements on Convair booster (B-15B-2) and North American Rockwell orbiter (161B) at nominal Mach number of 8Plotted and tabulated data from the thin-skin thermocouple phase of an experimental test program are presented. These data are representative of three events of simulated flight and are described as booster-orbiter ascent heating data, booster reentry heating data, and orbiter reentry heating data. The test was conducted in a 50-inch hypersonic tunnel b at a nominal Mach number of 8 and free-stream Reynolds number range of 700,000 to 3,700,000 per foot. The model employed was a 0.009 scale replica of the Convair B-15B-2 booster and North American Rockwell 161B orbiter.
Document ID
19720005229
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Warmbrod, J. D.
(MSFC)
Martindale, W. R.
(ARO, Inc.)
Matthews, R. K.
(ARO, Inc.)
Date Acquired
August 6, 2013
Publication Date
November 1, 1971
Subject Category
Space Vehicles
Report/Patent Number
DMS-DR-1177-VOL-1
NASA-CR-120009
Accession Number
72N12878
Funding Number(s)
CONTRACT_GRANT: NAS8-4016
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.