NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Reentry thermal protection from Pioneer F RTG insulation materialAblation tests were performed on the insulation material used in the Pioneer F radioisotope thermoelectric generator (RTG) in the Ames Arc-Heated Planetary-Gas Wind Tunnel. Test results indicate that the material, trade name Min-K 1301, should experience little ablation for heat transfer rates below 40 BTU/sq ft-sec. If the current design were to be changed so that the various pieces of Min-K were fastened or interlocked together the total amount of heat delivered to the RTG heat source during an earth orbital decay reentry would be reduced by at least 22.7%.
Document ID
19720008258
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Vorreiter, J. W.
(NASA Ames Research Center Moffett Field, CA, United States)
Date Acquired
September 2, 2013
Publication Date
January 1, 1972
Subject Category
Thermodynamics And Combustion
Report/Patent Number
NASA-TM-X-62100
Report Number: NASA-TM-X-62100
Accession Number
72N15908
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.