NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Tracer sensitive tapesA leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.
Document ID
19720008639
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Burrows, W. H.
(Georgia Inst. of Tech. Atlanta, GA, United States)
Burrows, W. H.
(Georgia Inst. of Tech. Atlanta, GA, United States)
Date Acquired
August 6, 2013
Publication Date
November 3, 1971
Subject Category
Instrumentation And Photography
Report/Patent Number
NASA-CR-123501
Report Number: NASA-CR-123501
Accession Number
72N16289
Funding Number(s)
PROJECT: PROJ. A-1308
CONTRACT_GRANT: NAS8-26759
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available