Pyrotechnic hazards classification and evaluation program. Electrostatic vulnerability of the E8 and XM15/XM165 clusters, phase 1A survey of the electrostatic vulnerability of explosive manufacturing plants and recommendations for reducing the vulnerability are discussed. During the course of the investigations, the XM15/XM165 and the E8 launcher were shown to be susceptible to electrostatic ignition. The pyrotechnic hazard of prime concern associated with electrostatics is that of the spark which can be generated. The heat, shock, and ionization produced by the spark can cause ignition of pyrotechnics. However, as a result of the initial ignition tests (XM15 fuse train), changes have been incorporated to make the fusing system relatively safe from premature electrostatic activation.