NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
X-ray scattering studyA soft X-ray glancing incidence telescope mirror and a group of twelve optical flat samples were used to study the scattering of X-rays. The mirror was made of Kanigen coated beryllium and the images produced were severely limited by scattering of X-rays. The best resolution attained was about fifteen arc seconds. The telescope efficiency was found to be 0.0006. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering then decreased with increasing angle of incidence until a critical angle was passed. At larger angles the scattering increased again. The samples all scattered more at 44 A than at 8 A. Metal samples were found to have about the same scattering at 44 A but greater scattering at 8 A than glass samples.
Document ID
19720012117
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Wriston, R. S.
(Martin Marietta Corp. Denver, CO, United States)
Froechtenigt, J. F.
(Martin Marietta Corp. Denver, CO, United States)
Date Acquired
August 6, 2013
Publication Date
February 1, 1972
Subject Category
Physics, Atomic, Molecular, And Nuclear
Report/Patent Number
MCR-72-31
NASA-CR-122362
Report Number: MCR-72-31
Report Number: NASA-CR-122362
Accession Number
72N19767
Funding Number(s)
CONTRACT_GRANT: NAS5-20287
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available