Identification of boiler inlet transfer functions and estimation of system parametersAn iterative computer method is described for identifying boiler transfer functions using frequency response data. An objective penalized performance measure and a nonlinear minimization technique are used to cause the locus of points generated by a transfer function to resemble the locus of points obtained from frequency response measurements. Different transfer functions can be tried until a satisfactory empirical transfer function of the system is found. To illustrate the method, some examples and some results from a study of a set of data consisting of measurements of the inlet impedance of a single tube forced flow boiler with inserts are given.
Document ID
19720019320
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Miles, J. H.
(NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
September 2, 2013
Publication Date
January 1, 1972
Subject Category
Thermodynamics And Combustion
Report/Patent Number
NASA-TM-X-68075
E-6485
Report Number: NASA-TM-X-68075
Report Number: E-6485
Meeting Information
Meeting: 1972 Joint Autom. Control Conf.
Location: Stanford, CA
Country: United States
Start Date: August 16, 1972
End Date: August 18, 1972
Sponsors: AIAA
Accession Number
72N26970
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.