NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
A flight-rated liquid-cooled garment for use within a full-pressure suitA flight rated liquid cooled garment system for use inside a full pressure suit has been designed, fabricated, and tested. High temperature tests with this system have indicated that heat is absorbed at a rate decreasing from 224 kg-cal/hr to 143 kg-cal/hr over a 40-min period. The first 30 min are very comfortable; thereafter a gradual heat load builds that results in mild sweating at the end of the 40-min period. In flight tests during hot weather when this cooling system was worn under a regulation flight suit, the pilot reported that temperatures were comfortable and that the garment prevented sweating.
Document ID
19720019471
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Carpenter, R.
(NASA Flight Research Center Edwards, CA, United States)
Winter, W. R.
(NASA Flight Research Center Edwards, CA, United States)
Date Acquired
August 6, 2013
Publication Date
January 1, 1972
Publication Information
Publication: Second Conf. on Portable Life Support Systems (SEE N72-27106 18-05)
Subject Category
Biotechnology
Accession Number
72N27121
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available