NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
A single axis electrostatic beam deflection system for a 5-cm diameter ion thrusterA single-axis electrostatic beam deflection system has been tested on a 5-cm diameter mercury ion thruster at a thrust level of about 0.43 mlb (25 mA beam current at 1400 volts). The accelerator voltage was 500 volts. Beam deflection capability of plus or minus 10 deg was demonstrated. A life test of 1367 hours was run at the above conditions. Results of the test indicated that the system could possibly perform for upwards of 10,000 hours.
Document ID
19720026090
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Lathem, W. C.
(NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
September 2, 2013
Publication Date
September 1, 1972
Subject Category
Propulsion Systems
Report/Patent Number
NASA-TM-X-68133
Report Number: NASA-TM-X-68133
Accession Number
72N33740
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available