NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Creep-rupture tests of internally pressurized Hastelloy-X tubesSeamless Hastelloy-X tubes with 0.375-in. outside diameter and 0.025-in. wall thickness were tested to failure at temperatures from 1400 to 1650 F and internal helium pressures from 800 to 1800 psi. Lifetimes ranged from 58 to 3600 hr. The creep-rupture strength of the tubes was from 20 to 40 percent lower than that of sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.
Document ID
19730008902
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Gumto, K. H.
(NASA Lewis Research Center Cleveland, OH, United States)
Colantino, G. J.
(NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
September 2, 2013
Publication Date
March 1, 1973
Subject Category
Materials, Metallic
Report/Patent Number
NASA-TM-X-2727
E-7234
Report Number: NASA-TM-X-2727
Report Number: E-7234
Accession Number
73N17629
Funding Number(s)
PROJECT: RTOP 501-24
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.