NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Reaction control system helium pressure regulator filter failureThe failure analysis of the command module reaction control system helium pressure regulators revealed that the filter element end caps were bulged by the helium pressure surge during activation. Some end caps may bulge and also some wire separation may occur during command module reaction control system activations; however, system performance should not be affected. The reaction control system design is acceptable and no change in hardware, system, or activation procedures is required.
Document ID
19730012100
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Date Acquired
September 2, 2013
Publication Date
December 1, 1972
Subject Category
Propulsion Systems
Report/Patent Number
MSC-07640
NASA-TM-X-69131
Report Number: MSC-07640
Report Number: NASA-TM-X-69131
Accession Number
73N20827
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available