NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Feasibility study of oxygen-dispensing emitters for thermionic converters, phase 1A metal/ceramic Marchuk tube was used to measure work functions of oxygen-doped tantalum, to determine applicability of the material to plasma-mode thermionic converters. Oxygen-doped tantalum was shown to increase in work function monotonically with oxygen doping in the range 0.1 to 0.3 atomic percent. Oxygenated test emitters were run at an average temperature of 2165 K and a T/T sub Cs ratio -5.8 to observe the influence of oxygen depletion. Bare work function decreased with outgassing of oxygen. Projections were made based on outgassing kinetics and area/volume ratios to calculate the longevity of oxygen doping in a practical converter. Calculations indicated that the program goal of 10,000 hr could be achieved at 1800 K with an initial oxygen doping of 1 atomic percent and a practical emitter area/volume ratio.
Document ID
19730016997
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Desteese, J. G.
(McDonnell-Douglas Astronautics Co. Richland, WA, United States)
Date Acquired
August 7, 2013
Publication Date
May 1, 1972
Subject Category
Nuclear Engineering
Report/Patent Number
MDC-G3144
NASA-CR-131837
Report Number: MDC-G3144
Report Number: NASA-CR-131837
Accession Number
73N25724
Funding Number(s)
CONTRACT_GRANT: NAS7-100
CONTRACT_GRANT: JPL-953125
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available