NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Feasibility of an on-line fission-gas-leak detection systemCalculations were made to determine if a cladding failure could be detected in a 100-kW zirconium hydride reactor primary system by monitoring the highly radioactive NaK coolant for the presence of I-131. The system is to be completely sealed. A leak of 0.01 percent from a single fuel pin was postulated. The 0.364-MeV gamma of I-131 could be monitored on an almost continuous basis, while its presence could be varified by using a longer counting time for the 0.638-MeV gamma. A lithium-drifted germanium detector would eliminate radioactive corrosion product interference that could occur with a sodium iodide scintillation detector.
Document ID
19730020985
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Lustig, P. H.
(NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
September 2, 2013
Publication Date
August 1, 1973
Subject Category
Nuclear Engineering
Report/Patent Number
E-7007
NASA-TM-X-2870
Report Number: E-7007
Report Number: NASA-TM-X-2870
Accession Number
73N29717
Funding Number(s)
PROJECT: RTOP 503-25
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available