NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Construction and testing of a gas-loaded, passive-control, variable-conductance heat pipeA methanol heat pipe using nitrogen gas for temperature control has been constructed and tested. The system was run over a power ratio of 15 (2 to 30 watts) with the heat source near ambient temperature and with the heat sink at a nominal value of 32 F. Control was obtained with a metal bellows gas reservoir which was actuated by an internal liquid-filled bellows. The liquid bellows was pressurized by expanding liquid methanol which was contained in an auxiliary reservoir in the evaporator heater block. It was demonstrated that the temperature variation of the heat source was reduced from 36 F for the heat pipe with no control to 7 F with the actuated bellows control.
Document ID
19730022152
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Depew, C. A.
(Washington Univ. Seattle, WA, United States)
Sauerbrey, W. J.
(Boeing Co. Seattle, United States)
Benson, B. A.
(Boeing Co. Seattle, United States)
Date Acquired
September 2, 2013
Publication Date
April 1, 1973
Subject Category
Thermodynamics And Combustion
Report/Patent Number
M-4-26-73
NASA-CR-114597
Report Number: M-4-26-73
Report Number: NASA-CR-114597
Accession Number
73N30884
Funding Number(s)
CONTRACT_GRANT: NASA ORDER A-52728-A
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available