Rotor windage losses for Lundell alternators.A range of experimental data was generated to permit accurate calculation of the windage power loss for Lundell alternator design. Windage tests were conducted on two concentric rotor-stator configurations in ambient air, producing Reynolds numbers as high as 100,000. Cylindrical rotors 10 and 12 inches in diameter were operated up to 24,000 rpm, and an 8 inch diameter Lundell rotor was operated up to 36,000 rpm. Gap-to-radius ratios of 0.01, 0.02 and 0.04 were tested. Tests were also conducted with axial slots machined on the stator surfaces to simulate alternator winding slots. Using the data obtained, a method was developed to calculate the windage loss for any Lundell alternator given the geometry and cavity conditions.