Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 6.0 ampere hour nickel-cadmium spacecraft cells with auxiliary electrodes for the atmospheric Explorer satellite C and DThe capacity of the cells ranged from 6.6 to 7.6 ampere hours during the three capacity tests. No voltage requirements or limits were exceeded during any portion of the test. All cells recovered to a voltage in excess of 1.193 volts during the 24-hour open-circuit portion of the internal short test. All the cells reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test. The average ampere/hours in and voltages at this pressure were 9.1 and 1.513, respectively. All cells exhibited pressure decay in the range of 1 to 5 psia during the last 30 minutes of the 1-hour open circuit stand. Average capacity out was 7.2 ampere/hours.
Document ID
19740011590
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Harkness, J. D.
(Naval Ammunition Depot Crane, IN, United States)
Date Acquired
September 3, 2013
Publication Date
January 2, 1974
Subject Category
Auxiliary Systems
Report/Patent Number
QEEL/C-74-1
NASA-CR-138985
Report Number: QEEL/C-74-1
Report Number: NASA-CR-138985
Accession Number
74N19703
Funding Number(s)
CONTRACT_GRANT: NASA ORDER S-23404-G
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.