NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Evaluation of magnetic refocusing in linear-beam microwave tubesMagnetic field configurations in which the axial component of the field decays linearly to a constant plateau field are evaluated for use in refocusing the output beam of linear beam microwave tubes. The slope of the decay and the value of the plateau field are parameters in this study. A uniform beam with a space charge force only in the radial direction is assumed, and the electron trajectories are computed for various classes. For a given magnetic configuration (slope and plateau value) the plateau length is calculated for a specified class and the rms deviation of the output angles for all classes is computed at the end of this plateau length. A minimum condition for a refocused beam is defined to be one in which the rms value of the output angles is less than the rms input. Many of the configurations satisfied this criteria and successfully reduced the rms value by half.