ASRDI oxygen technology survey. Volume 4: Low temperature measurementInformation is presented on temperature measurement between the triple point and critical point of liquid oxygen. The criterion selected is that all transducers which may reasonably be employed in the liquid oxygen (LO2) temperature range are considered. The temperature range for each transducer is the appropriate full range for the particular thermometer. The discussion of each thermometer or type of thermometer includes the following information: (1) useful temperature range, (2) general and particular methods of construction and the advantages of each type, (3) specifications (accuracy, reproducibility, response time, etc.), (4) associated instrumentation, (5) calibrations and procedures, and (6) analytical representations.