The M.I.T. Blowdown compressor facilityA blowdown compressor test facility has been developed which allows time-resolved aerodynamic testing of full-scale transonic compressor rotors at low cost. The rotor is brought to speed in vacuum, a diaphragm is opened, and the test gas is allowed to flow for a time of the order of 0.1 sec, during which the rotor is driven by its own inertia. Both 'steady-state' performance evaluation and detailed time resolution of the flow on the blade-passing time scale have been demonstrated for a two-ft-diam transonic rotor with a tangential Mach number of 1.2 and a nominal pressure ratio of 1.6. The steady-state performance as determined in the experiments includes an efficiency of 0.92 and a pressure ratio of 1.55 at design speed. The time-resolved measurements include the combination tone structure in the upstream flow field, resolved both axially and radially, and the wake structure downstream of the rotor, also resolved both radially and axially.
Document ID
19740044690
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Kerrebrock, J. L.
Epstein, A. H.
Haines, D. M.
Thompkins, W. T. (MIT Cambridge, Mass., United States)
Date Acquired
August 7, 2013
Publication Date
March 1, 1974
Subject Category
Facilities, Research, And Support
Report/Patent Number
ASME PAPER 74-GT-47Report Number: ASME PAPER 74-GT-47
Meeting Information
Meeting: Gas Turbine Conference and Products Show
Location: Zurich
Country: Switzerland
Start Date: March 30, 1974
End Date: April 4, 1974
Sponsors: American Society of Mechanical Engineers