NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Cost and size estimates for an electrochemical bulk energy storage conceptPreliminary capital cost and size estimates were made for a titanium trichloride, titanium tetrachloride, ferric chloride, ferrous chloride redox-flow-cell electric power system. On the basis of these preliminary estimates plus other important considerations, this electrochemical system emerged as having great promise as a bulk energy storage system for power load leveling. The size of this system is less than two per cent of that of a comparable pumped hydroelectric plant. The estimated capital cost of a 10 MW, 60- and 85-MWh redox-flow system compared well with that of competing systems.
Document ID
19750007089
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Warshay, M.
(NASA Lewis Research Center Cleveland, OH, United States)
Wright, L. O.
(NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
September 3, 2013
Publication Date
February 1, 1975
Subject Category
Energy Production And Conversion
Report/Patent Number
E-8138
NASA-TM-X-3192
Report Number: E-8138
Report Number: NASA-TM-X-3192
Accession Number
75N15161
Funding Number(s)
PROJECT: RTOP 506-23
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.